One-year outcomes after transcatheter insertion of an interatrial shunt device for the management of heart failure with preserved ejection fraction

Hausleiter, J; Neuzil, P; Hasenfuß, G; Bergmann, M; Feldman, T; Silvestry, FE; Trochu, JN; Walton, A; Muller, D; Jondeau, G; Ponikowski, P; Doughty, R; Burkhoff, D; Petrie, MC; Westenfeld, R; Kaye, DM; Rosenberg, M; Veldhuisen, DJ; Post, MC; Penicka, M; Raake, P; Walters, D; Hayward, C; Kolodziej, A
Abstract
BACKGROUND: Heart failure with preserved ejection fraction has a complex pathophysiology and remains a therapeutic challenge. Elevated left atrial pressure, particularly during exercise, is a key contributor to morbidity and mortality. Preliminary analyses have demonstrated that a novel interatrial septal shunt device that allows shunting to reduce the left atrial pressure provides clinical and hemodynamic benefit at 6 months. Given the chronicity of heart failure with preserved ejection fraction, evidence of longer-term benefit is required. METHODS AND RESULTS: Patients (n=64) with left ventricular ejection fraction ≥40%, New York Heart Association class II-IV, elevated pulmonary capillary wedge pressure (≥15 mm Hg at rest or ≥25 mm Hg during supine bicycle exercise) participated in the open-label study of the interatrial septal shunt device. One year after interatrial septal shunt device implantation, there were sustained improvements in New York Heart Association class (P<0.001), quality of life (Minnesota Living with Heart Failure score, P<0.001), and 6-minute walk distance (P<0.01). Echocardiography showed a small, stable reduction in left ventricular end-diastolic volume index (P<0.001), with a concomitant small stable increase in the right ventricular end-diastolic volume index (P<0.001). Invasive hemodynamic studies performed in a subset of patients demonstrated a sustained reduction in the workload corrected exercise pulmonary capillary wedge pressure (P<0.01). Survival at 1 year was 95%, and there was no evidence of device-related complications. CONCLUSIONS: These results provide evidence of safety and sustained clinical benefit in heart failure with preserved ejection fraction patients 1 year after interatrial septal shunt device implantation. Randomized, blinded studies are underway to confirm these observations. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01913613. © 2016 The Authors.
Journal CIRC HEART FAIL
ISSN 1941-3289
Published 01 Dec 2016
Volume 9
Issue 12
Pages e003662
DOI 10.1161/CIRCHEARTFAILURE.116.003662
Type Journal Article
Sponsorship